Reference Guide
PCI3001
Message Device option ROM on embedded NIC was successfully updated.
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 3 (Informational)
Trap/EventID 2419
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PCI3002
Message Failed to program virtual MAC address on a component at bus
arg1
device
arg2
function
arg3
.
Arguments
•
arg1 =
bus
•
arg2 =
device
•
arg3 =
func
Detailed
Description
Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support
FlexAddress.
Recommended
Response Action
Update BIOS, BMC/iDRAC, LOM, and mezzanine card firmware. If problem persists please
contact customer support.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 1 (Critical)
Trap/EventID 2417
LCD Message No LCD message display defined.
Initial Default. FALSE
603