Reference Guide
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD58
Message Unable to connect an ISO using Remote File Share (RFS).
Detailed
Description
The connect ISO operation using Remote File Share (RFS) failed.
Recommended
Response Action
Verify all the parameters are correct. If the problem persists. then reset iDRAC and retry the
operation.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD59
Message Unable to disconnect from ISO using Remote File Share (RFS).
Detailed
Description
Disconnecting ISO using Remote File Share (RFS) operation did not complete successfully.
Recommended
Response Action
Reset iDRAC and retry the operation.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
577