Reference Guide
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD21
Message Unable to boot to ISO image.
Detailed
Description
Booting to ISO has failed. Either BIOS was unable to boot to the ISO image or the provider did
not get a response in 5 minutes from BIOS on successful boot to ISO image.
Recommended
Response Action
1) Make sure that a POST error did not result in user interaction (Press F1 to continue or F2 to
run BIOS setup). 2) Reset iDRAC and rerun the command.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD22
Message Unable to detach ISO image from the host.
Detailed
Description
Unable to detach ISO image from the host because either the image is already detached, or
iDRAC may not be operating normally.
Recommended
Response Action
1) Rerun the command. 2) Reset iDRAC
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 1 (Critical)
560