Reference Guide
Detailed
Description
Unable to connect to Lifecycle Controller because of an existing open connection or an
internal error.
Recommended
Response Action
Reset iDRAC, and rerun the command to correct the problem.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD8
Message Setting Boot to PXE through IPMI failed.
Detailed
Description
The BIOS boot order set to PXE using a standard IPMI command has failed.
Recommended
Response Action
1) Check BIOS PXE settings. 2) Rerun the command. 3) Reset iDRAC and rerun the command.
Category Configuration
SubCategory OSD = OS Deployment
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
OSD9
Message Failed to reboot the system using an IPMI command.
Detailed
Description
Resetting the targeted server using the standard IPMI command has failed.
Recommended
Response Action
1) Rerun the command. 2) Reset iDRAC and rerun the command.
554