Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
LC003
Message Failed to change the firmware update mode.
Detailed
Description
An error occurred while trying to set the firmware update mode.
Recommended
Response Action
Verify that the firmware version supports this mode. Also confirm that the command and
parameters are correct. The parameter choices are: 1) Disable "0" (default) 2) Allow version
upgrade only "1" 3) Match firmware of replaced part "2"
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
LC004
Message Provisioning Server information is not formatted correctly.
Detailed
Description
The Provisioning Server parameter information is not formatted correctly.
Recommended
Response Action
Verify the string format. Enter a valid IP address or hostname for the Provisioning Server such
as: 1) hostname 2) hostname.domain.com 3) 1.1.1.1 4) hostname:8080 5) hostname.dell.com:8080
6) hostname1:80,hostname2:8080
Category Configuration
SubCategory LC = Lifecycle Contr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
436