Reference Guide

Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC3005
Message IO module
arg1
was inserted.
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC4000
Message A hardware incompatibility detected between BMC/iDRAC firmware and CPU.
Detailed
Description
A hardware incompatibility was detected between BMC/iDRAC firmware and Processor(s). An
iDRAC or BMC firmware update is needed.
Recommended
Response Action
Update the BMC/iDRAC firmware. If the problem persists, contact support.
Category System Health
SubCategory HWC = Hardware Config
388