Reference Guide

Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
Trap/EventID 2331
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC2011
Message The riser board cable or interconnect is not connected, or is improperly connected.
Detailed
Description
The riser blade cable may be necessary for proper operation. System functionality may be
degraded.
Recommended
Response Action
Check presence, then re-install or reconnect.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID 2329
LCD Message Riser board cable or interconnect failure. Check connection
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC2012
Message A fabric mismatch detected on fabric
arg1
with server in slot
arg2
.
Arguments
arg1 =
name
arg2 =
number
Detailed
Description
The fabric type on the server does not matach that of the IO module.
Recommended
Response Action
Check chassis fabric type in CMC GUI and compare to the type of IOM or mezzanine card.
Category System Health
383