Reference Guide

Severity Severity 2 (Warning)
Trap/EventID 2154
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
FAN0011
Message Fan
arg1
is enabled.
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory FAN = Fan Event
Severity Severity 3 (Informational)
Trap/EventID 2155
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
FAN0020
Message The
arg1
is non-functional.
Arguments
arg1 =
fan name
Detailed
Description
The fan identified in the message has failed or it is not installed correctly.
Recommended
Response Action
Remove and re-install the fan or replace the fan, and open the OMSA Web interface to verify if
the fan specified in the message is displayed correctly. If the issue persists, contact your
service provider.
Category System Health
348