Reference Guide
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
ENC40
Message A new enclosure was detected on
arg1
.
Arguments
•
arg1 =
controller name
Detailed
Description
The controller detected a new enclosure. This is due either to a hot plug of an enclosure, or a
power state change of an enclosure. In addition, this message is generated if the daisy chain
order of the enclosures changes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
Trap/EventID 4339
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
ENC5
Message Redundancy on
arg1
is degraded
Arguments
•
arg1 =
Enclosure Name
Detailed
Description
One or more of the enclosure components has failed. For example, a fan or power supply may
have failed. Although the enclosure is currently operational, the failure of additional
components could cause the enclosure to fail.
Recommended
Response Action
Identify and replace the failed component. To identify the failed component, select the
enclosure in the tree view and click the Health subtab. Any failed component will be identified
with a red X on the enclosures Health subtab. Alternatively, you can select the Storage object
335