Reference Guide

connections to it. Rerun the diagnostic.If no error occurs then it was a cable or connector
issue.
Category Storage
SubCategory DIAG = Diagnostic
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
DIAG0142
Message Hard Drive
arg1
- S/N
arg2
,
arg3
self test unsuccessful
arg4
.
Arguments
arg1 =
Drive Location
arg2 =
Serial Number
arg3 =
DST Short, or DST Long
arg4 =
Error Reason
Detailed
Description
Recommended
Response Action
If <Error Reason> is "terminated" then the disk controller terminated the test so a retry of the
test is advisable.Otherwise the hard drive should be replaced. {In the factory, this test type may
also be DEFT, in addition to DST Short and DST Long}
Category Storage
SubCategory DIAG = Diagnostic
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
287