Reference Guide

Arguments
arg1 =
Controller Name
Detailed
Description
The controller identified in the message has two connectors that are connected to the same
enclosure. The communication path on one connector has lost connection with the enclosure.
The communication path on the other connector is reporting this loss.
Recommended
Response Action
Make sure both the cables are securely attached to the enclosure and controller. FOr more
information about connecting the cables to the enclosure, see the Cables Attached Correctly
section in the PERC Users Guide. Also, make sure both Enclosure Management Modules
(EMMs) are healthy.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CTL216
Message Redundant path connection is restored on
arg1
.
Arguments
arg1 =
Controller Name
Detailed
Description
The communication in the redundant path on the connectors of the controller identified in the
message is restored.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
275