Reference Guide
the disk may be ok. If the multi-bit error occurs during a write operation, then data loss has
occurred.
Recommended
Response Action
Replace the Dual In-line Memory Module (DIMM). The DIMM is a part of the controller battery
pack. Refer to the storage hardware documentation for information on replacing the DIMM.
You may need to restore data from backup.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CTL41
Message Single-bit ECC error on
arg1
.
Arguments
•
arg1 =
Controller name
Detailed
Description
An error involving a single bit has been encountered during a read or write operation. The error
correction algorithm has corrected this error.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 2 (Warning)
Trap/EventID 4330
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CTL42
Message Enclosure Management Module (EMM) hot plug is not supported on
arg1
.
Arguments
•
arg1 =
Controller name
244