Reference Guide
Recommended
Response Action
1) Check system and operating system logs for exceptions. If no exceptions are found continue.
2) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 3) Make sure the processor is seated correctly. 4) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID 2241
LCD Message CPU <number> machine check error detected. Power cycle system
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE TRUE TRUE TRUE TRUE FALSE TRUE TRUE TRUE
CPU0800
Message CPU
arg1
voltage regulator module is present.
Arguments
•
arg1 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory CPU = Processor
Severity Severity 3 (Informational)
Trap/EventID 2243
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CPU0801
Message CPU
arg1
voltage regulator module failed.
Arguments
•
arg1 =
number
218