VLT402
Message The
arg1
sensor has returned to a normal state with a value of
arg2
Volts.
Arguments
•
arg1 =
sensor name
•
arg2 =
voltage
Detailed
Description
The voltage sensor identified in the message has returned to a normal state.
Recommended
Response Action
No response action is required.
Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT403
Message The
arg1
sensor state has changed to a warning state with a value of
arg2
Volts.
Arguments
•
arg1 =
sensor name
•
arg2 =
voltage
Detailed
Description
The voltage sensor identified in the message is faulty, or the voltage exceeds the preset
warning threshold. This condition can cause system performance issues and degradation in
the moitoring capability of the system.
Recommended
Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management
(ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2)
Re-configure the system to a minimum configuration, and verify if the sensor displays a normal
value, otherwise replace the system board. 3) If the sensor identified is a processor voltage
sensor, remove the processor module and inspect processor socket, and replace if required. If
the issue persists, contact your service provider.