Reference Guide

Recommended
Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management
(ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2)
Re-configure the system to a minimum configuration, and verify if the sensor displays a normal
value, otherwise replace the system board. 3) If the sensor identified is a processor voltage
sensor, remove the processor module and inspect processor socket, and replace if required. If
the issue persists, contact your service provider.
Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT401
Message Unable to read
arg1
sensor value.
Arguments
arg1 =
sensor name
Detailed
Description
A voltage sensor identified in the message may have failed. This condition can cause system
performance issues and degradation in the moitoring capability of the system.
Recommended
Response Action
Do one of the following to resolve the issue: 1) Verify the Embedded System Management
(ESM) Log for any sensor related faults. If there is a failed sensor, replace the system board. 2)
Re-configure the system to a minimum configuration, and verify if the sensor displays a normal
value, otherwise replace the system board. 3) If the sensor identified is a processor voltage
sensor, remove the processor module and inspect processor socket, and replace if required. If
the issue persists, contact your service provider.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
1471