Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR56
Message Redundancy of
arg1
has been degraded.
Arguments
arg1 =
virtual disk
Detailed
Description
This message occurs when a physical disk in the disk group was removed or when a physical
disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses
mirrored or parity information) and only one physical disk has failed, the virtual disk can be
rebuilt. Typically, the virtual disk (E.g. RAID 6) has multiple redundant disks and there is a
problem with one of them.
Recommended
Response Action
Replace the missing or failed physical disk.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR57
Message Background Initialization in
arg1
corrected medium error.
Arguments
arg1 =
VD Name
Detailed
Description
A disk media error was detected while the controller was completing a background task. A bad
disk block was identified. The disk block has been remapped.
Recommended
Response Action
Consider replacing the disk. If you receive this alert frequently, ensure to replace the disk. It is
recommended to routinely back up your data.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
1365