Reference Guide
Arguments
•
arg1 =
virtual disk
Detailed
Description
The background initialization task encountered errors that cannot be corrected. The virtual
disk contains physical disks that have unusable disk space or disk errors that cannot be
corrected.
Recommended
Response Action
Review other messages to identify whether the physical disk that has errors. If the virtual disk
is redundant, you can replace the physical disk and continue using the virtual disk. If the virtual
disk is non-redundant, you need to recreate the virtual disk after replacing the physical disk.
After replacing the physical disk, run a consistency check to verify the data.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID 4353
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VDR51
Message The consistency check process made corrections and completed on
arg1
.
Arguments
•
arg1 =
virtual disk
Detailed
Description
The consistency check completed on the virtual disk after making corrections.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
1362