Reference Guide
Detailed
Description
A redundant virtual disk has lost redundancy. This may occur when the virtual disk suffers the
failure of more than one physical disk. In this case, both the source physical disk and the target
disk with redundant data have failed. A rebuild is not possible because there is no longer
redundancy.
Recommended
Response Action
Replace the failed disks and restore from backup.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR5
Message
arg1
was deleted.
Arguments
•
arg1 =
virtual disk
Detailed
Description
The controller removed a virtual disk. This is due to a delete virtual disk operation, a reset
configuration operation, or the removal of every physical disk that was a member of the virtual
disk.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VDR50
Message Background Initialization (BGI) completed with uncorrectable errors on
arg1
.
1361