Reference Guide
BAR012
Message Unable to collect Lifecycle Controller data.
Detailed
Description
Lifecycle Controller data collection and export has failed.
Recommended
Response Action
1. Download and apply the Dell Update Package (DUP) for USC. 2. Run System Services to
update the database if CSIOR is not enabled. 3. Reboot the system and retry. If these
operations fail, download the Field Service Repair software and repair the Lifecycle Controller.
Download and install all the DUPs for USC, diagnostics, driver packs, and device firmware of
all the devices of the host system.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR014
Message Backup file or partition access error.
Detailed
Description
The ability to access the Backup file has been lost. The operation cannot continue. This can be
due to a media error or loss of connectivity.
Recommended
Response Action
if vFlash media replace media and try again. If a network share, make sure there is connectivity
to and existence of the destination.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE