Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
UEFI0013
Message CPU Exception Type 0x10: Floating Point Error (Software).
Detailed
Description
A CPU floating point error (type 0x10) exception occurred in the pre-boot UEFI environment.
Recommended
Response Action
Recently installed hardware or updated software may cause this exception. Update or remove
the hardware or software.
Category System Health
SubCategory UEFI = UEFI Event
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
UEFI0014
Message CPU Exception Type 0x11: Alignment Check (Software).
Detailed
Description
A CPU alignment check exception (type 0x11) occurred in the pre-boot UEFI environment.
Recommended
Response Action
Recently installed hardware or updated software may cause this exception. Update or remove
the hardware or software.
Category System Health
SubCategory UEFI = UEFI Event
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE