TMP502
Message The
arg1
sensor has returned to a normal state with a value of
arg2
degrees Celsius.
Arguments
•
arg1 =
sensor name
•
arg2 =
temperature
Detailed
Description
The sensor identified in the message has returned to a normal state.
Recommended
Response Action
No response action is required.
Category System Health
SubCategory TMP = Temperature
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
TMP503
Message The
arg1
sensor state has changed to a warning state with a value of
arg2
degrees Celsius.
Arguments
•
arg1 =
sensor name
•
arg2 =
temperature
Detailed
Description
The temperature sensor identified in the message is faulty, or the temperature exceeds the
warning threshold. This condition can cause system performance issues and degradation in
the moitoring capability of the system.
Recommended
Response Action
Verify the Embedded System Management (ESM) Log for any sensor related faults. If there is a
failed sensor, replace the system board. For more information, contact your service provider.
Otherwise, change the warning threshold for the temperature sensor (if applicable) such that it
corresponds to the hardware configuration.
Category System Health
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
Trap/EventID FALSE
1315