Reference Guide

Recommended
Response Action
Obtain a valid host system backup image and try the operation again. Reboot the remote
access controller and try the operation again. If the error continues, download a new remote
access controller firmware image and try the operation again.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR085
Message Unable to collect System Information for Import Backup file validation.
Detailed
Description
The validation of the system profile backup file has failed. The retrieval of system information to
validate the backup file has failed.
Recommended
Response Action
Restart the remote access controller, and retry the operation. If the error continues, use the
remote access controller firmware to try the operation again.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR086
Message Unable to Restore The Lifecycle Controller Configuration database.
Detailed
Description
The system profile import of Lifecycle Controller configuration data has failed.
Recommended
Response Action
If collect system inventory on reboot (CSIOR) is not enabled, enter and exit System Services in
USC to update the database, reboot the system and try the operation again. If the error
continues, use the field service repair software to repair the Lifecycle Controller. Download all
128