Reference Guide
Detailed
Description
An error occurred while copying the system configuration XML file from the network share.
Recommended
Response Action
If the file is being copied from an NFS share, make sure that it is accessible from iDRAC. If the
file is being copied from a CIFS share, make sure that it is accessible from iDRAC using the
share credentials provided. Test the network share access using the Test Network Connection
method. For more information, see the Lifecycle Controller Users Guide.
Category Configuration
SubCategory SYS = System Info
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SYS047
Message Input file for system configuration XML is not compliant with configuration schema.
Detailed
Description
The input file is not compliant with the system configuration XML schema.
Recommended
Response Action
Make sure that the input file is compliant with the system configuration schema published on
delltechcenter.com/lc.
Category Configuration
SubCategory SYS = System Info
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SYS048
Message System configuration XML input file contains invalid characters,
arg1
at line
arg2
.
Arguments
•
arg1 =
character
1273