Reference Guide
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SYS115
Message The power cord sensor is non-functional.
Detailed
Description
The power cord sensor becomes non-functional because of one of the following reasons: 1)
The power cable may not be connected properly or disconnected. 2) The power cord sensor in
the power supply unit has failed. However, the power supply unit may still function. 3) There is
an input power failure.
Recommended
Response Action
Do of the following to resolve the issue: 1) Reconnect the power cord to the power supply unit.
2) Replace the power supply unit that has the failed power cord sensor, with a new power
supply unit. 3) Make sure that the input power supply is restored.
Category System Health
SubCategory SYS = System Info
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SYS116
Message Unable to determine the status of the power cord.
Detailed
Description
The status of the power cord cannot be determined because of one of the following reasons: 1)
The power cable may not be connected properly or disconnected. 2) The power cord sensor in
the power supply unit has failed. However, the power supply unit may still function. 3) There is
an input power failure.
Recommended
Response Action
Do of the following to resolve the issue: 1) Reconnect the power cord to the power supply unit.
2) Replace the power supply unit that has the failed power cord sensor, with a new power
supply unit. 3) Make sure that the input power supply is restored.
Category System Health
SubCategory SYS = System Info