Reference Guide

LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR076
Message Unable to collect the Configuration database.
Detailed
Description
The collection and export of Lifecycle Controller Configuration Database failed.
Recommended
Response Action
Enter System Services in USC, and select Exit and Reboot to reset and update the database. If
the error continues repair the Lifecycle Controller, apply the Dell Update Packages for USC,
diagnostics, device firmware and driver pack and retry the operation.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR077
Message Unable to collect the Firmware images.
Detailed
Description
The collection and export of host system firmware images failed.
Recommended
Response Action
Apply Dell Update Packages for all devices and software, and try the operation again. If the
error continues, repair the Lifecycle Controller and apply the packages again, and retry the
operation.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
124