Reference Guide

Firmware Update feature and retry the operation. 2) Reboot the system, press the <F10> key to
re-enter Lifecycle Controller, and retry the operation..
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0030
Message Unable to complete the backup Server Profile backup operation.
Detailed
Description
iDRAC is unable to complete the backup Server Profile operation.
Recommended
Response Action
Reset iDRAC and retry the operation. To reset the iDRAC, hold the System ID button down for
15 seconds or longer and wait for 90 seconds for the iDRAC to restart. For more information on
the error, see the Lifecycle Log.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0031
Message Unable to initiate the backup Server Profile backup operation.
Detailed
Description
iDRAC is unable to initiate the backup Server Profile operation because an unrecoverable error
occurred.
Recommended
Response Action
Reset iDRAC and retry the operation. To reset the iDRAC, hold the System ID button down for
15 seconds or longer and wait for 90 seconds for the iDRAC to restart. For more information on
the error, see the Lifecycle Log.
Category Configuration
1150