Reference Guide
Recommended
Response Action
Reset iDRAC and retry the operation. To reset the iDRAC, hold the System ID button down for
15 seconds or longer and wait for 90 seconds for the iDRAC to restart. For more information on
the error, see the Lifecycle Log.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0029
Message Unable to retrieve status of backup Server Profile operation.
Detailed
Description
Status of backup Server Profile operation could not be retrieved because an unrecoverable
error occurred while communicating with iDRAC.
Recommended
Response Action
Reset iDRAC and retry the operation. To reset the iDRAC, hold the System ID button down for
15 seconds or longer and wait for 90 seconds for the iDRAC to restart. For more information on
the error, see the Lifecycle Log.
Category Configuration
SubCategory SWC = Software Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC0065
Message Unable to retrieve the drivers for the selected operating system.
Detailed
Description
Lifecycle Controller is unable to copy the OS drivers from the OS driver pack.
Recommended
Response Action
Exit the OS Deployment wizard and retry the operation. If the issue persists, do one of the
following:1) Update the system with the latest operating system driver packs using the
1149