Reference Guide
Recommended
Response Action
Enter the iDRAC configuration utility. Select the System Services option in the main selection
screen. Choose the "Cancel Lifecycle Controller Actions" / "Cancel System Services" operation
and follow the directions to ensure this operation is performed. If "Cancel Lifecycle Controller
Actions" / "Cancel System Services" is not available, remove power from the system, wait 1
minute and reapply power. If this fails to correct the issue contact Customer Support.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR055
Message Previously stored configuration values not applied to Device:
arg1
Arguments
•
arg1 =
device name
Detailed
Description
Attempted configuration import was not successful for the specified device.
Recommended
Response Action
The system event log captures the values that were not set, and must be reset manually.
Category Configuration
SubCategory BAR = Backup/Restore
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
BAR056
Message Component Configuration Restored on Device :
arg1
Arguments
•
arg1 =
device name
114