Reference Guide
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR0105
Message No enclosures are displayed.
Detailed
Description
No enclosure data to display. The system is powered off, enclosures are not present on the
system, or enclosures are not connected to the RAID controllers.
Recommended
Response Action
Check if the server has power, enclosures are available, and enclosures are connected to the
RAID controllers.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR0106
Message Fans are not connected to enclosures or data about fans is unavailable.
Detailed
Description
No fan data to display. The system is powered off, no fan enclosures are present in the system,
or the fans are not connected to the enclosures.
Recommended
Response Action
Check if the server has power, enclosure fan is available, and fan is connected to the
enclosure.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
1078