Reference Guide
Recommended
Response Action
Exit Lifecycle Controller, press the <F10> key to re-enter Lifecycle Controller, and retry the
operation. If the problem persists, update the RAID controller firmware to the latest version and
retry the operation.
Category Storage
SubCategory STOR = Storage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
STOR0101
Message No RAID controller is displayed.
Detailed
Description
No RAID controller data to display. The system is powered off, no RAID controller is present in
the system, or the RAID controller is not connected to the system.
Recommended
Response Action
Check if the server has power, RAID controller is available, and that a RAID controller is
connected to the system.
Category Storage
SubCategory STOR = Storage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
STOR0102
Message No batteries are displayed.
Detailed
Description
No battery data to display. The system is powered off, batteries are not present on the system,
batteries are not connected to the RAID controller, or the batteries are depleted.
Recommended
Response Action
Check if the server has power, batteries are available, and batteries are connected to the RAID
controller.
Category Storage
1076