Reference Guide

Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SEL1211
Message The time-stamp clock could not be synchronized.
Detailed
Description
The time stamp on system event log events may not correlate to the system time. (IPMI sensor
type code 12h - offset 05h)
Recommended
Response Action
Cycle system input power, if problem persists call support.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SEL1300
Message No bootable media found.
Detailed
Description
System setup displays the system boot order. The local video screen may also show additional
information. (IPMI sensor type code 1eh - offset 00h)
Recommended
Response Action
Check system boot settings. Check mass storage controller configuration settings is
applicable.