Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SEC0052
Message Chassis intrusion sensor may have failed.
Detailed
Description
The chassis intrusion sensor may have failed, because of this it cannot be determined whether
the chassis is closed or opened. This condition can lead to degraded system performance
because of insufficient cooling. The system security may be compromised.
Recommended
Response Action
Replace the chassis intrusion sensor. For more information, contact your service provider.
Category System Health
SubCategory SEC = Security Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. TRUE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
DONTKN
OW
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SEC0700
Message Warning: Default username and password are currently in use. It is strongly recommended to
change the default password before configuring the propery. Else, it causes a severe security
risk for iDRAC.
Detailed
Description
If the property name is configured without changing the default password, iDRAC may be
accessible on the Internet. This causes a severe security risk for iDRAC.
Recommended
Response Action
To change the password, run the following racadm command: racadm set
iDRAC.Users.<index>.Password <new password string>. Alternatively, to avoid this warning
message, run the following racadm command: racadm set
iDRAC.Tuning.DefaultCredentialWarning Disable.
Category Configuration
SubCategory SEC = Security Event
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
1002