Release Notes
• DRAC4 service failure message after YUM installation. (391720)
RAC4 service startup shows failed to probe DRAC4 when OpenManage installation is performed
using YUM or if all the RAC rpms are installed from the OpenManage DVD.
Essentially this error message is observed on a system (9G, 10G, or 11G server) that does not have
a RAC4 but RAC4 rpms are installed. There is no functionality impact.
The following message is displayed:
DRAC4 probe: DRAC4 pci device not found [FAILED]
Versions Affected: 7.1 and earlier
• Linux install script cannot be run from Virtual Media.
The "srvadmin-services.sh" script cannot be run from Virtual Media.
Run this script from the local file system after un-mounting the virtual media. This avoids
input/output errors that you may otherwise encounter while using Virtual Media.
Versions Affected: 7.1 and earlier
• YUM uninstall leaves services running. (410584)
If you are using methods other than the "srvadmin-uninstall.sh" command to uninstall OpenManage
rpm, the OpenManage service processes may still continue to run.
To prevent this, run the “srvadmin-services stop” command to stop the OpenManage services and
then remove the OpenManage rpms.
Versions Affected: 7.0 and earlier
Dell OpenManage Power Center --> Group
Management with OpenManage Power Center
Collects and sums aggregate power use -rack, row, room
Implement policies for power reduction in response to power or cooling events
Maximize rack utilization based on actual, not faceplate data
Global Support
For information on technical support, visit
dell.com/contactus
.
For information on documentation support, visit support.dell.com/manuals. On the Manuals
page, click Software
‐
>Systems Management. Click on the specific product on the right
‐
side to
access the documents.