Reference Guide
Back to Contents Page
Supported Dell Remote Access Controllers and Solutions
Dell™SystemsSoftwareSupportMatrix5.5
Supported Microsoft Windows Operating Systems for the DRAC
Supported Linux Operating Systems for the DRAC
RAC Firmware Versions
Dell™RemoteAccessController(DRAC)isasystemsmanagementhardwareandsoftwaresolutiondesignedtoprovideremotemanagementcapabilities,
crashed system recovery, and power control functions.
By communicating with the system's Baseboard Management Controller (BMC), the DRAC (when installed) can be configured to send e-mail alerts for warnings
or errors related to voltages, temperatures, intrusion, and fan speeds. DRAC also logs event data and the most recent crash screen (for systems running the
Microsoft Windows operating system only) to help diagnose the probable cause of a system crash.
For more information on DRAC, see the Dell Remote Access Controller User's Guide available on the Dell Support website at support.dell.com or on the
DellSystemsManagementToolsandDocumentation DVD.
Supported Dell Remote Access Controller versions and firmware, as well as supported BMC IPMI protocol versions, are listed in Table5-1. Table5-1 lists the
following DRAC types:
l Integrated Dell Remote Access Controller (iDRAC)
l Dell Remote Access Controller 5 (DRAC 5)
l Dell Remote Access Controller/Modular Computer (DRAC/MC)
l Dell Remote Access Controller 4 (DRAC 4)
l Dell Remote Access Controller III/XT (DRAC III/XT)
l Dell Embedded Remote Access/Modular Computer (ERA/MC) controller
l Dell Embedded Remote Access/Option (ERA/O) controller
l Dell Embedded Remote Access (ERA) controller
l Dell Remote Access Card III (DRAC III)
Table 5-1.SupportedRemoteAccessControllersandSolutions
NOTE: M805, M905, T100, and PowerVault DL2000 are scheduled to be available in second half of 2008.
NOTE: The DRAC III occupies a PCI slot, and has a modem, a battery, and an external AC power connection unlike the other RACs.
Dell System
Dell Remote Access Controllers (DRACs)
Baseboard Management Controller (BMC)
DRAC Type
Supported DRAC Firmware Version
Integrated BMC
BMC Firmware Version
Supported IPMI Protocol Versions
M805
iDRAC
1.2
X (CMC)
1.29 or later
2.0
M905
iDRAC
1.2
X (CMC)
1.29 or later
2.0
T605
DRAC 5
1.40
X
2.30
2.0
R905
DRAC 5
1.40
X
2.31
2.0
T300
DRAC 5
1.40
X
2.34
2.0
R300
DRAC 5
1.40
X
2.34
2.0
M600
iDRAC
1.2
X (CMC)
1.29 or later
2.0
M605
iDRAC
1.2
X (CMC)
1.29 or later
2.0
R805
DRAC 5
1.40
X
1.29 or later
2.0
R900
DRAC 5
1.40
X
2.27
2.0
R200
DRAC 4
1.61
X
1.29 or later
2.0
6950
*
DRAC 5
1.40
X
2.29
2.0
2970
*
DRAC 5
1.40
X
2.29
2.0
2950
*
DRAC 5
1.40
X
2.28
2.0
2900
*
DRAC 5
1.40
X
2.28
2.0
1955
DRAC/MC
1.50
X
1.10 or later
2.0
1950
*
DRAC 5
1.40
X
2.28
2.0
1900
*
DRAC 5
1.40
X
2.29
2.0
6850
DRAC 4
1.61
X
1.40 or later
1.5
6800
DRAC 4
1.61
X
1.40 or later
1.5
2850
DRAC 4
1.61
X
1.23 or later
1.5
2800
DRAC 4
1.61
X
1.23 or later
1.5