Reference Guide

Table6-7 and Table6-8showtheotherelementssupportedbythePERC3/Di.
Table 6-7.StorageManagementServiceSupportedElements:PERC3/Di
Table 6-8.StorageManagementServiceSupportedElements:PERC3/Di
Storage Management Service*
Dell OpenManage Version
PERC Firmware Version
Windows 2000
Driver
Windows Server
2003
Driver
Windows Server
®
2008
1.1 on a PowerEdge 1650
4.3
2.8.0.6092
2.8.0.6085
2.8.0.6085
NA
1.1 on a PowerEdge 2650
4.3
2.8.0.6092
2.8.0.6085*
2.8.0.6085*
NA
1.1 on a PowerEdge 4600
4.3
2.8.0.6092
2.8.0.6085*
2.8.0.6085*
NA
1.2 on a PowerEdge 1650
4.4
2.8.0.6092
2.8.0.6085*
2.8.0.6085
NA
1.2 on a PowerEdge 2650
4.4
2.8.0.6092
2.8.0.6085*
2.8.0.6085*
NA
1.2 on a PowerEdge 4600
4.4
2.8.0.6092
2.8.0.6085*
2.8.0.6085*
NA
2.0 on a PowerEdge 1650
5.0
2.8.0.6098
2.8.0.6085*
2.8.0.6085*
NA
2.0 on a PowerEdge 2650
5.0
2.8.0.6098
2.8.0.6085*
2.8.0.6085*
NA
2.0 on a PowerEdge 4600
5.0
2.8.0.6098
2.8.0.6085*
2.8.0.6085*
NA
2.1 on a PowerEdge 1650
5.1
2.8.0.6098
2.8.0.6085*
2.8.0.6085*
NA
2.1 on a PowerEdge 2650
5.1
2.8.0.6098
2.8.0.6085*
2.8.0.6085*
NA
2.1 on a PowerEdge 4600
5.1
2.8.0.6098
2.8.0.6085*
2.8.0.6085*
NA
2.2 on a PowerEdge 1650
5.2
2.8.1-6098
NA
2.8.0.6084
NA
2.2 on a PowerEdge 2650
5.2
2.8.1-6098
NA
2.8.0.6084
NA
2.2 on a PowerEdge 4600
5.2
2.8.1-6098
NA
2.8.0.6084
NA
2.3 on a PowerEdge 1650
5.3
2.8.1-7692
NA
2.8.0.6084
2.8.1.7691
2.3 on a PowerEdge 2650
5.3
2.8.1-7692
NA
2.8.0.6084
2.8.1.7691
2.3 on a PowerEdge 4600
5.3
2.8.1-7692
NA
2.8.0.6084
2.8.1.7691
* The 1.1.4 Linux driver is included in the Red Hat Package Manager (RPM) 2302.
NOTE: Microsoft Windows Server 2008 is scheduled to be available in the first half of 2008. For latest information, see
http://www.microsoft.com/windowsserver2008/default.mspx.
Storage Management
Service*
Dell OpenManage
Version
PERC Firmware
Version
Red Hat
Enterprise
Linux 3
Driver
Red Hat Enterprise
Linux 4
Driver
Red Hat Enterprise
Linux Server 5
Driver
SUSE Linux Enterprise Server
(versions 9 and 10)
1.1 on a PowerEdge
1650
4.3
2.8.0.6092
1.1.4*
NA
NA
NA
1.1 on a PowerEdge
2650
4.3
2.8.0.6092
1.1.4*
NA
NA
NA
1.1 on a PowerEdge
4600
4.3
2.8.0.6092
1.1.4*
NA
NA
NA
1.2 on a PowerEdge
1650
4.4
2.8.0.6092
1.1.4*
1.1.5.2372
NA
NA
1.2 on a PowerEdge
2650
4.4
2.8.0.6092
1.1.4*
1.1.5.2372
NA
NA
1.2 on a PowerEdge
4600
4.4
2.8.0.6092
1.1.4*
1.1.5.2372
NA
NA
2.0 on a PowerEdge
1650
5.0
2.8.0.6098
1.1.4*
1.1.5.2392
NA
NA
2.0 on a PowerEdge
2650
5.0
2.8.0.6098
1.1.4*
1.1.5.2392
NA
NA
2.0 on a PowerEdge
4600
5.0
2.8.0.6098
1.1.4*
1.1.5.2392
NA
NA
2.1 on a PowerEdge
1650
5.1
2.8.0.6098
1.1.4*
1.1.5.2392
NA
NA
2.1 on a PowerEdge
2650
5.1
2.8.0.6098
1.1.4*
1.1.5.2392
NA
NA
2.1 on a PowerEdge
4600
5.1
2.8.0.6098
1.1.4*
1.1.5.2392
NA
NA
2.2 on a PowerEdge
1650
5.2
2.8.1-6098
NA
1.1.5.2372.1
NA
NA
2.2on a PowerEdge
2650
5.2
2.8.1-6098
NA
1.1.5.2372.1
NA
NA
2.2 on a PowerEdge
4600
5.2
2.8.1-6098
NA
1.1.5.2372.1
NA
NA
2.3 on a PowerEdge
1650
5.3
2.8.1-7692
NA
1.1.5.2372.1
NA
NA