Connectivity Guide
Table 475. AC Power Switch Capabilities
Variable Name: DellACPowerSwitchCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
unknownCapabilities(1)
The AC power switch’s capabilities are unknown.
inputSourceCord1NoReturnCapable(2)
Input source is AC power cord 1, with no return.
inputSourceCord1ReturnCapable(4)
Input source is AC power cord 1, with return.
inputSourceCord2NoReturnCapable(8)
Input source is AC power cord 2, with no return.
inputSourceCord2ReturnCapable(16)
Input source is AC power cord 2, with return.
inputSourceSharedCapable(32)
Input source is shared.
Table 476. AC Power Switch Settings
Variable Name: DellACPowerSwitchSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The AC power switch’s settings are unknown.
inputSourceCord1NoReturn(2)
Input source is AC power cord 1, with no return.
inputSourceCord1Return(4)
Input source is AC power cord 1, with return.
inputSourceCord2NoReturn(8)
Input source is AC power cord 2, with no return.
inputSourceCord2Return(16)
Input source is AC power cord 2, with return.
inputSourceShared(32)
Input source is shared.
Table 477. AC Power Switch Redundancy Mode
Variable Name: DellACPowerSwitchRedundancyMode
Data Type: Integer
Possible Data Values Meaning of Data Value
nonRedundant(1)
The AC power switch is not expecting redundancy.
redundant(2)
The AC power switch is expecting redundancy.
Table 478. AC Power Cord State Capabilities
Variable Name: DellACPowerCordStateCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The AC power cord’s capabilities are unknown.
onlineCapable(2)
The AC power cord can be disabled (offline) or enabled
(online).
notReadyCapable(4)
The AC power cord’s capabilities are not ready.
Table 479. AC Power Cord State Settings
Variable Name: DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values Meaning of Data Value