CLI Guide

Table 56. Valid Parameters of omconfig chassis remoteaccess config=user id=<
user id
>
dracusergroup=custom or omconfig mainsystem remoteaccess config=user id=<
user id
>
dracusergroup=custom (continued)
name=value pair 1 name=value pair 2 name=value pair 3 Description
executeservercommands=true
| false
true or false: Enables or
disables execution of server
commands.
accessconsoleredir=true |
false
true or false: Enables or
disables access to console
redirection.
accessvirtualmedia=true |
false
true or false: Enables or
disables access to virtual
media.
testalerts=true | false true or false: Enables or
disables test alerts.
Usage of Extipmiusergroup
The following table displays the usage of extipmiusergroup=custom:
Table 57. Usage Of extipmiusergroup
name=value pair 1 name=value pair 2 name=value pair 3 Description
config=user
id=user id
extipmiusergroup=custom
NOTE:
extipmiusergroup
user group is available
only on the Dell 10G blade
systems.
id=user id
loginidrac=true | false true or false: Enables or
disables logging into iDRAC.
configureidrac=true | false true or false: Enables or
disables configuration of
iDRAC.
Omconfig Chassis Temps Or Omconfig Mainsystem Temps
Use the omconfig chassis temps or omconfig mainsystem temps command to set warning thresholds for
temperature probes. As with other components, you can view both warning and failure threshold values, but you cannot set
failure threshold values. The system manufacturer sets the minimum and maximum failure threshold values.
NOTE: Threshold values that you can set vary from one system configuration to another.
Valid Parameters For Temperature Warning Thresholds
The following table displays the valid parameters for setting temperature warning thresholds:
Table 58. Valid Parameters For Omconfig Chassis Temps Or Omconfig Mainsystem Temps
name=value pair Description
index=<n> Number of the probe or probe index (specify).
90 Omconfig Managing Components Using The Instrumentation Service