You cannot default one value and set another. In other words, if you default the minimum warning threshold value, you are also
selecting the default value for the maximum warning threshold value.
Specifying a value for minimum and maximum warning thresholds
If you prefer to specify values for the fan probe warning thresholds, you must specify the number of the probe you are
configuring and the minimum and/or maximum warning threshold values. In the following example, the probe that is being
configured is probe 0. The first command sets only the minimum threshold; the second sets the minimum and maximum
thresholds:
omconfig chassis fans index=0 minwarnthresh=4580
or
omconfig mainsystem fans index=0 minwarnthresh=4580
omconfig chassis fans index=0 minwarnthresh=4580 maxwarnthresh=9160
or
omconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the following message is displayed:
Fan probe warning threshold(s) set successfully.
Omconfig chassis frontpanel or omconfig mainsystem frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to:
● configure the power button and the Nonmasking Interrupt (NMI) button
● configure the LCD to display:
○ No information
○ Custom information
○ Default system information
○ Service tag, system name
○ Remote access MAC addresses
○ System power
○ Remote access IP address
○ Ambient temperature of the system
○ Remote access IPv4 address
○ Remote access IPv6 address
● Specify and configure the LCD line number
● View the encryption state report of the LCD
● Configure LCD to indicate an active remote session when the Kernel-based Virtual Machine (KVM) is available
NOTE: You can configure the Power and NMI buttons only if they are present on the system.
The following table displays the valid parameters for the command:
Table 49. Valid Parameters Of Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel
name=value pair 1 name=value pair 2 Description
lcdindex=<index> NA Specifies the LCD line number.
config=none | default | custom NA
● none: Sets the LCD text to none.
● default: Sets the LCD text to
default.
76 Omconfig Managing Components Using The Instrumentation Service