CLI Guide

Table 97. omreport Temperature Probe Commands (continued)
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs Use
Example for SCSI controllers:
controller=0 enclosure=2 info=temps.
Example for SAS controllers: controller=0
enclosure=1:2 info=temps
controller=id
enclosure=<ENCLOSUREID> info=temps
index=n where id is the controller number
and <ENCLOSUREID> is the enclosure
number and n is the number of a
temperature probe. For example:
controller=0 enclosure=2 info=temps
index=1
Displays the temperature probes for the
specified enclosure.
Omreport Fan Status
The following table describes the syntax for the omreport Fan commands:
Table 98. omreport Fan Status
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
controller=id
enclosure=<ENCLOSUREID> info=fans
where id is the controller number and
ENCLOSUREID is the enclosure number.
For example: controller=0 enclosure=2
NOTE: For SCSI controllers, the ID
specified in
enclosure=<ENCLOSUREID> is the
connector number and for Serial
Attached SCSI (SAS) controllers, ID
is the
connectorNumber:EnclosureIndex.
Displays the fans for the specified
enclosure.
controller=id
enclosure=<ENCLOSUREID> info=fans
index=n where id is the controller
number and ENCLOSUREID is the
enclosure number and n is the number of
a fan. For example: controller=0
enclosure=2 info=fans index=1
Displays the specified fan.
Omreport Power Supply Status
The following table describes the syntax for the omreport Power Supply commands:
Table 99. Omreport Power Supply Commands
Required Command Levels (1, 2, 3)
and name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all
enclosures attached to the system.
Omreport storage commands 135