Users Guide

Table Of Contents
Table 58. Virtual Disk Specifications for PERC S100, PERC S110, PERC S130, PERC S300 , PERC S140
and PERC S150 Controllers (continued)
Virtual Disk
Specification
PERC S100 PERC S110 PERC S130 PERC S300 PERC S140 PERC S150
Maximum Number
of Physical Disks
in a RAID 0
8 4 10 8 16 16
Maximum
Physical Disks in a
RAID 1
2 2 2 2 2 2
Maximum Number
of Physical Disks
in a RAID 5
8 4 10 8 16 16
Maximum Number
of Physical Disks
in a RAID 10
4 4 10 4 16 16
Minimum Number
of Physical Disks
that Can Be
Concatenated
NA NA NA NA NA NA
Minimum Number
of Physical Disks
in a RAID 0
2 2 2 2 2 2
Minimum Number
of Physical Disks
in a RAID 1
2 2 2 2 2 2
Minimum Number
of Physical Disks
in a RAID 5
3 3 3 3 3 3
Minimum Number
of Physical Disks
in a RAID 10
4 4 4 4 4 4
NOTE: When creating virtual disks using software RAID controllers, the information related to the physical disks linked
to the virtual disk is enumerated or displayed on Storage Management after a short delay. This delay in displaying the
information does not cause any functional limitation. If you are creating partial virtual disks, it is recommended that you
provide Storage Management adequate time between each partial virtual disk creation process.
NOTE: RAID 1 VD on SWRAID controller will enumerate for the attribute Stripe Element Size as NA.
RAID Levels Supported By The PERC Software RAID Controllers
Table 59. RAID Levels Supported by the PERC S100, PERC S110, PERC S130, PERC S300, PERC S140 and
PERC S150 Controllers
RAID Level PERC S100 PERC S110 PERC S130 PERC S300 PERC S140 PERC S150
RAID 0 Yes Yes Yes Yes Yes Yes
RAID 1 Yes Yes Yes Yes Yes Yes
RAID 5 Yes No Yes Yes Yes Yes
RAID 10 Yes No Yes Yes Yes Yes
RAID 50 No No No No No No
RAID 6 No No No No No No
Supported Features 191