Release Notes
• JIT-96670: On systems running VMware operating systems if the sfcbd-watchdog is stopped abruptly before completion of the
SNMP traps for storage task is logged. Semaphore leak is observed.
Workaround: Run the sfcbd-watchdog until SNMP traps for storage task is completed.
• JIT-96484: Auto Config RAID 0 task fails and displays improper error message, when there are no free drives to create RAID 0 virtual
disks on the server. Exit the wizard of the error page as Server Administrator log out.
Workaround: Once again login to OMSA GUI.
• JIT-97151: Full view of Physical Disk Page in Server Administrator GUI, the negotiated speed for a 6Gbps drive capable speed is
intermittently shown as 12Gbps.
• JIT-94842: Storage Management carries SHA1 signed library ( storelibIR) in the current release.
• JIT-95176: The Physical disks available in MX5016s connected to MX7000 chassis slot 8 does not support RAID-10 intelligent mirror
virtual disk creation.
• JIT-92467: The dynamic mapping of an enclosure for the first time also displays the unmapped enclosure for a short period. Refresh
the Server Administrator page to remove the unmapped enclosure entries.
• JIT-104975: In storage management, FAN speed changes will not update dynamically.
Workaround: Data manager service restart will update the latest FAN speed.
• JIT-106970:After change controller mode operation is performed, two alerts that are generated have the same alert ID and
description.
• If the controller name is not displayed in the alert message, check the controller information for mapping the controller ID and
controller name.
• JIT-106295: Critical and warning a lert is not displayed on Enhanced Event Message alert for Physical Device and Controller ID on
Available Spare threshold.
• JIT-103891: Duplicate alerts for power supply removal are displayed while enclosure power supply cable is removed.
• JIT-103962: The Storage Management displays the removal and insertion alerts intermittently on EMM for HBA controllers during
physical drive hot-plug-out and hot-plug-in.
• JIT-104973: On enhanced mode, an alert is displayed as A Device is inserted in the enclosure for both Power unit and FAN inserted
into enclosure. The message does not state the specific device inserted.
• JIT-97106: You cannot create a partial RAID50 or a RAID60 virtual disk from IDRAC/HII. When the Foreign configuration drives are
imported on the first RAID50 or RAID60 virtual disk with physical drive that is created on Storage Management.
• JIT-103150: On PowerEdge R940XA with dual backplane, the Storage tree does not display the Enclosure ID intermittently during
insertion or removal of multiple drives.
Workaround: Restart the Data-Manager service to resolve this discrepancy.
• JIT-94890: For fully populated chassis, the Storage Management system takes few minutes to load the storage components.
• JIT-101739: If an EMM is removed from MX5016s sled, EMM failure or removal alert is not observed on Server Administrator alerts.
• JIT-109008: Storage Management is enumerating more than one backplane that is not connected to SWRAID controller under
SWRAID controller (S140) on PowerEdge R740xd2 system.
• JIT-98675: On Server Administrator page, a delay is observed on hot-pluggable devices when hot-plugged in or out on HBA 330
MMZ.
• JIT-117535: On the Web Server the Command Line Interface commands does not display the correct exit codes for all sub-queries
when Server Administrator services is not running.
• JIT-110132: When the enclosure is hot plug-in to the 12GBPS HBA controller observes an additional physical disk id in alert log page.
• JIT-109207: Server Administrator displays incorrect capacity information of the drive when formatted with 4096 block size.
• JIT-108887: The alert log displays a message as XML not well-formed after a server restart and post controller mode change
operation intermittently.
Work-around: Clear Logs and restart the service.
• JIT-113370: RAID 10 virtual disk creation using intelligent mirroring fails, as the support is not available from this release of
OpenManage.
• JIT-117535 : On the Web Server the Command Line Interface commands does not display the correct exit codes for all subqueries
when Server Administrator services is not running.
• JIT-110132 : When the enclosure is hot plug-in to the 12GBPS HBA controller observes an additional physical disk id in alert log page.
Dell EMC OpenManage Release Notes Version 9.4
15