Release Notes

DF384061: Self-signed certificate does not enable the compatibility listener in Windows 2008 R2 managed node. On a Windows 2008
R2 managed node, a valid CA signed certificate is required to create compatibility mode WinRM Listener. You cannot create a
compatibility mode listener with a self-signed certificate.
DF380725: On Internet Explorer or Firefox Web browsers, you cannot attach files to an e- mail if the filename contains non-ASCII
letters. To attach files to an e-mail, rename files to contain ASCII characters.
On YX2X generation of PowerEdge servers, Server Administrator displays the Embedded Systems Management (ESM) or hardware
logs. However, when the maximum limit for number of logs that can be recorded is reached, the existing oldest logs are overwritten.
But for YX1X generation of PowerEdge servers or prior, when the maximum limit is reached, the information logging is stopped.
DF523827: On Citrix XenServer 6.0 or later, if the Alert on Console alert action is configured from the Server Administrator CLI or
GUI, the alert message may not be displayed in a readable format.
BITS113585: Server Administrator does not log CPU or CMOS Battery Probe Alerts and does not send SNMP traps.
To resolve this issue, stop the USB arbitration service and run the Inventory Collector. To stop the USB arbitration service:
1. Run the ps aux|grep usb command to check if the USB arbitration service is running.
2. Run the chkconfig usbarbitrator off command to prevent the USB arbitration service from starting during boot.
3. After the USB arbitrator service is stopped, reboot the server to allow the Inventory collector to run.
DF520449: On all versions of the ESX, the following USB connection error messages are generated. These messages can be ignored.
The following is a typical message:
Table 1. USB connection error message
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
Table 2. USB connection error message
Vendor: iDRAC Model: SECUPD Rev: 0329
Type: Direct-Access ANSI SCSI revision: 02
DF531509: The setup and/or system password configuration from the Server Administrator GUI or CLI is successful, but the
password is displayed as blank instead of asterisk (*) on the F2 BIOS page.
BITS086423: After an upgrade to the current version, Server Administrator does not retain the support link information on the
Preferences page.
BITS091830: Distributed Web Server (DWS) connection does not work if you have installed the sblim-sfcb rpm from SLES11 SP3
operating system DVD. To make the connection work, install sblim-sfcb rpm either from SLES11 SP2 or from OM DVD.
BITS040184: User in IDRAC user authentication page showing operator privilege(IDRAC user privileges) is displayed as Custom in
Server Administrator.
With the following wsman rpm versions getting carried in SLES12 OS,OMSA DWS does not work. Update these rpms having same or
later versions from SUSE
openwsman-server-2.4.11-2.18.x86_64.rpm ,libwsman1-2.4.11-2.18.x86_64.rpm,
libwsman_clientpp1-2.4.11-2.18.x86_64.rpm
On clicking the apply button twice on the BIOS setup page, the Server preference page and SNMP configuration page the Server
Administrator will logout from the current session.
Dell EMC OpenManage Release Notes Version
9.4
The following section describes the issues and workaround in Server Administrator Storage Management.
Topics:
Known Issues and Workarounds for Storage Management Service
Installation Prerequisites
Installation Procedure
2020 - 02
Dell EMC OpenManage Release Notes Version 9.4 11