Connectivity Guide
enableCapable(2)
Setup BIOS is capable of enabling the network interface.
enableWithoutPXECapable(4)
Setup BIOS is capable of enabling the NIF without Pre-boot
eXecution Environment (PXE).
Table 1156. Network Interface Control Settings
Variable Name: DellNetworkInterfaceControlSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
Network interface state is unknown.
enabled(2)
Network interface is enabled.
enabledWithoutPXE(4)
Network interface is enabled without PXE.
Table 1157. BIOS Setting Value Type
Variable Name: DellBIOSSettingValueType
Data Type: Integer
Possible Data Values Meaning of Data Value
integer(1)
Value type is integer.
string(2)
Value type is string.
enumeration(3)
Value type is enumeration.
orderedList(4)
Value type is ordered list.
Local Response Agent Group
The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA
allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the
loss of redundancy in a specific component or the elevation of temperature in a chassis. Systems managers can configure the LRA to
respond to an event type with a specific action. When the condition of the critical component worsens, the systems manager can escalate
the response to make it more obvious to the operator.
For example, when a voltage probe on a monitored machine reaches a warning condition, the systems manager may want to notify the
operator by causing the machine to beep. When the voltage probe reaches failure, the systems manager might want to have the system
that has a failing component send a broadcast message to the management system and power off the troubled system.
LRA Group Tables
The following management information base (MIB) tables define LRA variable attributes:
• LRA Global Settings Table
• LRA Action Table
LRA Global Settings
The global settings table allows the systems manager to determine what LRA capabilities exist for a specific system that is running Server
Administrator. Some machines may support all or some of the capabilities described in DellLocalResponseAgentCapabilitiesUnique. The
LRA Global Settings Table also defines thermal shutdown capabilities and settings. In the event that a temperature probe determines the
temperature is at or over the failure limit, the systems manager can set an action to be taken automatically.
Table 1158. LRA Global Settings Table
Name
lRAGlobalSettingsTable
Object ID 1.3.6.1.4.1.674.10892.1.1500.10
Description Defines the LRA Global Settings Table.
248 Server Administrator Group