CLI Guide

name=value pair 1
config=
name=value pair 2 Description
config=advsol characcuminterval=number
number: Sets the character accumulate interval in 5
millisecond intervals.
charsendthreshold=number
number: Sets the number of characters. BMC automatically
sends a serial over LAN data packet that contains the number
of characters as soon as this number of characters (or
greater) has been accepted from the baseboard serial
controller into the BMC.
enableipmi= true | false
true: Enables IPMI over LAN.
false: Disables IPMI over LAN.
enablenic=true | false
true: Enables DRAC NIC.
false: Disables DRAC NIC
nicselection=sharedwithfailoveronall | nic1 |
teamednic1nic2 | dracnic
sharedwithfailoveronall: Configures the new NIC selection
option.
nic1: Enables NIC 1.
teamednic1nic2: Enables NIC teaming functionality.
dracnic: Enables DRAC NIC if DRAC 5 is installed.
NOTE: The nicselection option is supported only
on PowerEdge 11G systems. From PowerEdge YX2X
systems onwards, primarynw and failovernw
replaces nicselection.
primarynw=dedicated | lom1 | lom2 | lom3 |
lom4
dedicated: Configures dedicated port as primary network for
remote access.
NOTE: This option requires license to configure
primarynw as dedicated. If the appropriate
license is not installed or has expired, the system
displays an error message. For more information,
see
Dell License Manager
at dell.com/
openmanagemanuals.
lom 1: Configures lom1 port as the primary network for
remote access.
lom 2: Configures lom2 port as the primary network for
remote access.
lom 3: Configures lom3 port as the primary network for
remote access.
lom 4: Configures lom4 port as the primary network for
remote access.
NOTE: The primarynw option is supported from
PowerEdge YX2X systems onward. If the
primarynw is set to dedicated, then set
failovernw to none.
NOTE: If the primarynw is set to dedicated, then
set failovernw to none.
failovernw=none | lom1 | lom2 | lom3 | lom4
| all
none: Configures the failover network to none.
lom 1: Configures the failover network to lom 1.
lom 2: Configures the failover network to lom 2.
80 Omconfig Managing Components Using The Instrumentation Service