CLI Guide

Event Name Description
event=intrusion Sets action or enables or disables alert generation when a chassis is opened.
event=powerwarn Sets action or enables or disables alert generation when a power device probe detects that
the power supply, voltage regulator module, or DC to DC converter is pending a failure
condition.
event=powerabsent Sets action or enables or disables alert generation when a processor probe detects that the
power supply is absent.
event=powerfail Sets action or enables or disables alert generation when a power device probe detects that
the power supply, voltage regulator module, or DC to DC converter has failed.
event=processorwarn Sets action or enables or disables alert generation when a processor probe detects that the
processor is running at less than peak performance or speed.
event=processorfail Sets action or enables or disables alert generation when a processor probe detects that the
processor has failed.
event=processorabsent Sets action or enables or disables alert generation when a processor probe detects that the
processor is absent.
event=redundegrad Sets action or enables or disables alert generation when the system fans and/or power
supplies become inoperative, resulting in less than full redundancy for that component.
event=redunlost Sets action or enables or disables alert generation when the system fans and/or power
supplies become inoperative, resulting in a lost or a no redundant components working
condition for that component.
event=systempowerwarn Sets actions when a power consumption probe detects a warning value.
event=systempowerfail Sets actions when a power consumption probe detects a failure value.
event=tempwarn Sets action or enables or disables alert generation when a temperature probe detects that
the temperature is approaching the maximum high or low limits.
event=removableflashmediapresent Sets actions that Server Administrator performs when the system detects a removable flash
media.
event=removableflashmediawarn Sets actions that Server Administrator performs when a removable flash media warning is
displayed.
event=removableflashmediafail Sets actions that Server Administrator performs when a removable flash media fails.
event=tempfail Sets action or enables or disables alert generation when a temperature probe detects that
the temperature is either too high or low for proper operation.
event=voltfail Sets action or enables or disables alert generation when a voltage probe detects that the
voltage is too low for proper operation.
event=intdualsdcardcritical Sets actions that Server Administrator performs when an internal dual SD card critical event
occurs.
event=intdualsdcardwarn Sets actions that Server Administrator performs when an internal dual SD card warning is
displayed.
event=intdualsdcardabsent Sets actions that Server Administrator performs when an internal dual SD card is not
available.
event=intdualsdcardredunlost Sets actions that Server Administrator performs when the redundancy of an internal dual SD
card is lost.
event=watchdogasr Enables or disables alert generation configured by the ASR when the system has hung or is
not responding.
Omconfig system snmptraptest or omconfig servermodule
snmptraptest
Use the omconfig system snmptraptest or omconfig servermodule snmptraptest command to send the snmp test
trap to the destination address if Server Administrator SNMP component is configured in the configuration file.
106
Omconfig Managing Components Using The Instrumentation Service