Release Notes

JIT-113370: RAID 10 virtual disk creation using intelligent mirroring fails, as the support is not available from this release of
OpenManage.
JIT-117535 : On the Web Server the Command Line Interface commands does not display the correct exit codes for all
subqueries when Server Administrator services is not running.
JIT-110132 : When the enclosure is hot plug-in to the 12GBPS HBA controller observes an additional physical disk id in alert
log page.
JIT-112768 : On systems running Suse Linux Enterprise 15.0 operating system the device protocol of Intel NVMe P4800x
devices displays NVMe 0.0 instead of NVMe 1.0.
JIT-113374: While creation of R10, R50 and R60 virtual disks the Storage Management does not display the dedicated
hot-spare suggestions for all disks, if the user selects different size of physical disks as part of virtual disk creation.
Work around: Dedicated hot-spare can be assigned after creation of virtual disk using assign or unassign dedicated hot-spare
option.
JIT-111625 and JIT-112746: In a maximum configuration setup i.e. eight enclosures connected to PERC H840 controller,
performing creating or deleting virtual disk operation multiple times with more than 160 plus physical drives on systems
running ESXi operating system.We observe core or virtual disk creation failure.
Work around: Restart sfcbd service.
JIT-108887: On Storage Management, observes intermittently malformed alert log showing XML Data generated for the
selection made is not well formed on systems running ESXi operating system.
Work around: Restart sfcbd service.
JIT-119082 : On multipath mode, if clear redundant path option is performed immediately after removing the enclosure
cable, few minutes of delay is observed on Server Administrator GUI to refresh.
Recommendation : It is recommended to wait for the Redundant path broken alerts before performing the clear redundant
path. If in case Server Administrator page delay is observed, wait for few minutes to return to the normal state page or
restart the service.
JIT-120251: The foreign physical disks connected to the system, on reaching the maximum number of supported virtual disk
by the controller is displayed on the Import Preview page as Orphan Drive.
JIT-117872: On performing the unblink operation on physical disk connected to 12Gbps SAS HBA, observing both health and
activity LEDs light turn off.
JIT-121226: Storage Management is enumerating connector health status as HHHL AIC status in SWRaid NVMe
configuration. Correct health status of HHHL card is seen on HHHL enumeration page.
JIT-121358: The Cryptographic erase capable for SATA SED drives is displayed as no in the physical disk attribute. However
the physical disk task will have the Cryptographic erase operation and there is no functionality impact.
JIT-125130: On deleting the encrypted virtual disk created with SED disks on EKM enabled controller, the Encrypted
physical disk property attribute of SED disks is shown as Yes instead of No.
JIT-125128: When an encrypted virtual disk, created on server with EKM enabled controller, is hot plugged in a server with
non-EKM or LKM enabled controller, the foreign configuration wizard shows blank page instead of listing all the foreign
configurations.
JIT-128978 : When there is failed virtual disk in the same controller the Import foreign configuration on controllers task,
does not list the available degraded virtual disks to import, recover or clear. The list can be observed after failed virtual disk
deletion.
JIT-136314: The NVMe device protocol for Intel NVMe P4800x devices is displayed as NVMe 1.1 instead of NVMe 1.0 on
supported Linux distros .
JIT-147761: Blink and unblink operation under virtual disk tasks in SWRAID is blocked, if any of the participating physical disk
is HHHL add in card. Blink and unblink operation is also blocked for Non Raid HHHL add in card virtual disk.
On BOSS and SWR controller the failed alert for the physical disk part number will be displayed as NULL.
Storage Management does not allow creation of 240 virtual disks, if spanned virtual disks are present in system.
On UI if the submit button is clicked more than once an internal error may occur, but the task will be performed successfully.
JIT-146959, JIT-151162: On HBA345 controller the Slot Occupancy Report may show an incorrect amount of drive slots
depending on server model and chassis.
JIT-147942: The BGI progress bar value in Virtual Disk page does not clear on PowerEdge R7525 server with SWRAID S150
controller and NVME setup.
JIT-151734: The vendors Part Number field may be blank for certain NVMe devices.
On PERC and HBA Controller PDR16,PDR51,PDR7 and PDR22 events are generated once in 24 hours.
On PERC and HBA Controller use a single event PDR16 for the events PDR16 and PDR19.
JIT-151771: If configuring a RAID-10 virtual disk on a software RAID controller OMSA may not suggest the proper physical
disk within sequence to maintain a fully redundant span.
17