Release Notes

Critical Threshold for PCIe SSDs is set to %1" respectively, instead of "The Available Spare Warning Threshold for PCIe SSDs
is set to <value>" and "The Available Spare Critical Threshold for PCIe SSDs is set to <value>".
JIT-80079: On a system with S140 controller, when prepare to remove operation is performed on a non-RAID NVMe drive,
the Virtual disk bus protocol for the VD associated with that drive is shown as SATA, instead of PCIe SSD.
JIT-97576: On systems running Vmware ESXi operating systems for BOSS controller, an alert is displayed as rebuild
completed which requires service restart to log the alerts.
JIT-94666: For Non-RAID drives attached to SWRAID controller enumerates for virtual Disk layout as Non-RAID. Whereas
on Storage Management GUI, when you click on virtual disk name the physical drives does not display as Non-RAID.
JIT-96670: On systems running VMware operating systems if the sfcbd-watchdog is stopped abruptly before completion of
the SNMP traps for storage task is logged. Semaphore leak is observed.
Workaround: Run the sfcbd-watchdog until SNMP traps for storage task is completed.
JIT-96484: Auto Config RAID 0 task fails and displays improper error message, when there are no free drives to create RAID
0 virtual disks on the server. Exit the wizard of the error page as Server Administrator log out.
Workaround: Once again login to OMSA GUI.
JIT-97151: Full view of Physical Disk Page in Server Administrator GUI, the negotiated speed for a 6Gbps drive capable
speed is intermittently shown as 12Gbps.
JIT-94842: Storage Management carries SHA1 signed library ( storelibIR) in the current release.
JIT-95176: The Physical disks available in MX5016s connected to MX7000 chassis slot 8 does not support RAID-10
intelligent mirror virtual disk creation.
JIT-92467: The dynamic mapping of an enclosure for the first time also displays the unmapped enclosure for a short period.
Refresh the Server Administrator page to remove the unmapped enclosure entries.
JIT-104975: In storage management, FAN speed changes will not update dynamically.
Workaround: Data manager service restart will update the latest FAN speed.
JIT-106970:After change controller mode operation is performed, two alerts that are generated have the same alert ID and
description.
If the controller name is not displayed in the alert message, check the controller information for mapping the controller ID
and controller name.
JIT-106295: Critical and warning a lert is not displayed on Enhanced Event Message alert for Physical Device and Controller
ID on Available Spare threshold.
JIT-103891: Duplicate alerts for power supply removal are displayed while enclosure power supply cable is removed.
JIT-103962: The Storage Management displays the removal and insertion alerts intermittently on EMM for HBA controllers
during physical drive hot-plug-out and hot-plug-in.
JIT-104973: On enhanced mode, an alert is displayed as A Device is inserted in the enclosure for both Power unit and FAN
inserted into enclosure. The message does not state the specific device inserted.
JIT-97106: You cannot create a partial RAID50 or a RAID60 virtual disk from IDRAC/HII. When the Foreign configuration
drives are imported on the first RAID50 or RAID60 virtual disk with physical drive that is created on Storage Management.
JIT-103150: On PowerEdge R940XA with dual backplane, the Storage tree does not display the Enclosure ID intermittently
during insertion or removal of multiple drives.
Workaround: Restart the Data-Manager service to resolve this discrepancy.
JIT-94890: For fully populated chassis, the Storage Management system takes few minutes to load the storage
components.
JIT-101739: If an EMM is removed from MX5016s sled, EMM failure or removal alert is not observed on Server
Administrator alerts.
JIT-109008: Storage Management is enumerating more than one backplane that is not connected to SWRAID controller
under SWRAID controller (S140) on PowerEdge R740xd2 system.
JIT-98675: On Server Administrator page, a delay is observed on hot-pluggable devices when hot-plugged in or out on HBA
330 MMZ.
JIT-117535: On the Web Server the Command Line Interface commands does not display the correct exit codes for all
sub-queries when Server Administrator services is not running.
JIT-110132: When the enclosure is hot plug-in to the 12GBPS HBA controller observes an additional physical disk id in alert
log page.
JIT-109207: Server Administrator displays incorrect capacity information of the drive when formatted with 4096 block size.
JIT-108887: The alert log displays a message as XML not well-formed after a server restart and post controller mode
change operation intermittently.
Work-around: Clear Logs and restart the service.
16