Users Guide

Table Of Contents
For information on alert messages, see the Server Administrator Messages Reference Guide.
Supported Controllers
NOTE: The firmware and drivers listed in the Server Administrator Release Notes refer to the minimum supported version
for these controllers. Later versions of the firmware and drivers are also supported. For the most recent driver and firmware
requirements, contact your service provider.
This release of Storage Management supports the following controllers.
Supported RAID Controllers
Storage Management supports the following RAID controllers. For information on the technology used by the supported RAID
controllers, see RAID Controller Technology: SATA and SAS.
PERC S100, PERC S110, PERC S130, PERC S300, PERC S140, PERC 150
PERC H330 Adapter, PERC H330 Mini Monolithic, PERC H330 Mini Blades, PERC H330 Embedded, PERC H730 Adapter,
PERC H730 Mini Monolithic, PERC H730 Mini Blades, PERC H730P Adapter, PERC H730P Mini Monolithic, PERC H730P
Mini Blades, PERC H730P Slim, and PERC H830 Adapter
PERC H840 Adapters
PERC H740P Adapter, PERC H740P Mini Monolithic
PERC FD33xD/FD33xS
PERC H730P MX, PERC H745P MX
PERC H745P Front, PERC H345 Front
PERC H745 Adapter, PERC H345 Adapter
NOTE:
The order of the controllers displayed on Storage Management may differ with the order of the controllers displayed
in the Human Interface (HII) and PERC Option ROM. The order of the controllers does not cause any limitation.
Supported Non-RAID Controllers
Storage Management supports the following non-RAID controllers:
SAS 12 Gbps HBA
HBA 330
HBA 330 MX
HBA 330 MMZ
HBA 345 Adapter
HBA 345 Frnt
NOTE:
When a backplane without an expander (passive backplane) is connected to an HBA 330 controller, the enumeration
of the physical disks is split between Connector 0 and Connector 1. For example, if the passive backplane is populated
with a maximum of eight physical disks, the first four physical disks are listed under Connector 0 and the remaining four
physical disks are listed under Connector 1. You will be able to view all the eight physical disks only if both bays are
connected. If one bay is connected, only the physical disks associated with that bay are displayed.
NOTE: For SAS 12 Gbps HBA and HBA 330 controller, the Available Reports that can be viewed are View Slot Occupancy
Report and View Physical Disk Firmware Version Report.
NOTE: A logical connector is displayed under the PERC 10.x and HBA 330 controllers, and all the physical disks will be
detected under this logical connector.
NOTE: At times, the connector ID for SAS 12 Gbps HBA may not be displayed correctly on Storage Management. This
occurs because of a firmware limitation in the SAS 12 Gbps HBA. However, this connector ID discrepancy does not cause
any functional limitation.
12 Overview