Users Guide
NOTE: For information about license management, see the
Dell License Manager User’s Guide
available at dell.com/
openmanagemanuals.
Conguring Remote Access Device Users
To congure Remote Access Device users using the Remote Access page:
1 Click the Modular Enclosure > System/Server Module > Main System Chassis/Main System > Remote Access object.
2 Click the Users tab.
The Remote Access Users window displays information about users that can be congured as BMC/iDRAC users.
3 Click User ID to congure a new or existing BMC/iDRAC user.
The Remote Access User Conguration window allows you to congure a specic BMC/iDRAC user.
4 Specify the following general information:
• Select Enable User to enable the user.
• Enter the name for the user in the User Name eld.
• Select the Change Password check box.
• Enter a new password in the New Password eld.
• Re-enter the new password in the Conrm New Password eld.
5 Specify the following user privileges:
• Select the maximum LAN user privilege level limit.
• Select the maximum serial port user privilege granted.
6 Specify the User group for DRAC/iDRAC user privileges.
7 Click Apply Changes to save changes.
8 Click Back to Remote Access User Window to go back to the Remote Access Users window.
NOTE
: Six additional user entries are congurable when DRAC is installed. This results in a total of 16 users. The same
username and password rules apply to BMC/iDRAC and RAC users. When DRAC/iDRAC6 is installed, all the 16 users
entries are allocated to DRAC.
Setting Platform Event Filter Alerts
To congure the most relevant BMC features, such as Platform Event Filter (PEF) parameters and alert destinations using Server
Administrator Instrumentation Service:
1 Click the System object.
2 Click the Alert Management tab.
3 Click Platform Events.
The Platform Events window allows you to take individual action on specic platform events. You can select those events for which
you want to take shutdown actions and generate alerts for selected actions. You can also send alerts to specic IP address
destinations of your choice.
NOTE
: You must be logged in with Administrator privileges to congure the BMC PEF
Alerts.
NOTE: The Enable Platform Event Filters Alerts setting disables or enables PEF alert generation. It is independent of
the individual platform event alert settings.
NOTE: System Power Probe Warning and System Power Probe Failure are not supported on the PowerEdge systems
without PMBus support although Server Administrator allows you to congure them.
4 Choose the platform event for which you want to take shutdown actions or generate alerts for selected actions and click Set
Platform Events.
Working with remote access controller