Users Guide
For 12G systems, the Primary Network options for Remote Management (iDRAC7) NIC are: LOM1, LOM2, LOM3, LOM4, and
Dedicated. The Failover Network options are: LOM1, LOM2, LOM3, LOM4, All LOMs, and None.
NOTE: The Dedicated option is available when the iDRAC7 Enterprise License is present and valid.The number of LOMs
varies based on the system or hardware conguration.
• Enable IPMI Over LAN
• IP Address Source
• IP Address
• Subnet Mask
• Gateway Address
• Channel Privilege Level Limit
• New Encryption Key
5 Congure the following optional VLAN conguration details:
NOTE: VLAN conguration is not applicable for systems with iDRAC.
• Enable VLAN ID
• VLAN ID
• Priority
6 Congure the following IPv4 Properties:
• IP Address Source
• IP Address
• Subnet Mask
• Gateway Address
7 Congure the following IPv6 Properties:
• IP Address Source
• IP Address
• Prex Length
• Default Gateway
• DNS Address Source
• Preferred DNS Server
• Alternate DNS Server
NOTE
: You can congure the IPv4 and IPv6 address details only if you enable the IPv4 and IPv6 properties under
Additional Conguration.
8 Click Apply Changes.
Conguring The Remote Access Device To Use A
Serial Port Connection
To congure the BMC for communication over a serial port connection:
1 Click the Modular Enclosure > System/Server Module > Main System Chassis/Main System > Remote Access.
2 Click the Conguration tab.
3 Click Serial Port.
The Serial Port Conguration window appears.
4 Congure the following details:
• Connection Mode Setting
• Baud Rate
Working with remote access controller
63